Product Identification

Product ID:ICP-MS CALIBRATION STANDARD, ICPMS-3
MSDS Date:03/10/1992
FSC:6810
NIIN:00N044300
MSDS Number: BTLTZ

Responsible Party
SPEX IND INC
3880 PARK AVE
EDISON, NJ 08820
US

Emergency Phone: 800-424-9300(CHEMTREC)

Info Phone: 201-549-7144

Preparer: VANAJA SIVAKUMAN

Cage: IO044

Contractor
SPEX IND INC
EDISON, NJ 08820 US

Telephone: 908-549-7144

Cage: IO044

Ingredients

HYDROCHLORIC ACID; (HYDROGEN CHLORIDE)

CAS: 7647-01-0

RTECS: MW4025000

Fraction By Weight: 10%

OSHA PEL 5 PPM, C

ACGIH TLV: 5 PPM, C

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


SEV IRRIT OF UPPER RESP TRACT, INFLAMM & EDEMA OF

RTECS: 9999999ZZ


BURNING OF THROAT, INFLAMM OF NOSE & A CHOKING

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:CONCENTRATED HYDROCHLORIC ACID MAY BE
FATAL IF INHALED, INGEST/ABSORBED THRU SKIN. HYDROCHLORIC ACID
VAP/MIST IS AN IRRITANT OF EYES, MUC MEMB, SKIN & UPPER RESP TRACT.
WHEN CONCENTRATED HYDROCHLORIC ACID IS IN CONT W/EYES, IT PRDCES
SEV BURNS WHICH MAY RSLT IN PRLNGD/PERM VISUAL IMPAIRMENT, INCL
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: TOTAL LOSS OF VISION. ON SKIN,
CONCENTRATED LIQ/VAP WILL CAUSE RED, PAIN & SEV BURNS. RPTD/PRLNTD
EXPOS TO DILUTE SOLN MAY CAUSE DERM. EROSION OF TEETH MAY OCCUR
W/PRLNGD EXPOS TO CONCENTRAT ED HYDROCHLORIC ACID. INGEST OF LIQ
CAUSES SEV BURNS OF MUC MEMB OF MOUTH, ESOPHAGUS, & STOM CAUSING;
PAIN (SUPP DATA)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYES: FLUSH WITH WATER FOR AT LEAST 15 MINUTES OCCAS LIFT
LIDS. SKIN: REMOVE CONTAMINATED CLOTHING, THEN FLUSH W/WATER FOR AT
LEAST 15 MINUTES. WASH CLOTHING THOROUGHLY BEFORE REUSE. INHAL:
MOVE TO FR ESH AIR. INGEST: DO NOT INDUCE VOMITING. IMMED GET MED
HELP. SEND TO HOSPITAL. ONLY IF PATIENT IS CONSCIOUS, GIVE LG QTY
OF WATER/MILK. IF IRRIT CONTINUES, GET MED ATTN IMMED.

Fire Fighting

Extinguishing Media:APPROPRIATE TO SURROUNDING FIRE CONDITIONS.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE.

Accidental Release

Spill Release Procedures:VENT AREA. DILUTE SPILL W/WATER & NEUT W/SODA
ASH, LIMESTONE, ETC. WIPE UP & PUT INTO A SEALED CONTR FOR PROPER
DISP. WASH SPILL SITE OFF W/WATER AFTER MATL PICKUP IS COMPLETE.
WEAR CHEM RESIST GLASSE S, GLOVES & CLTHG. WEAR NIOSH/MSHA APPRVD
RESP.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:HYDROCHLORIC ACID WILL ATTACK MOST
METALS AND SOME FORMS OF PLASTICS, RUBBER, AND COATINGS. STORE @
ROOM TEMPS. KEEP TIGHTLY SEALED WHEN NOT IN USE.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR.
Ventilation:CHEMICAL FUME HOOD.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM SAFETY GOGGLES
Other Protective Equipment:LAB COAT. HAVE IMMED AVAILABILITY OF AN
EYEWASH IN CASE OF EMERGENCY. DELUGE SHOWER .
Work Hygienic Practices:WASH CAREFULLY AFTER USE.
Supplemental Safety and Health
MATLS TO AVOID:HYDROCHLORIC ACID COMES INTO CONT W/MOST METALS IT
CORRODES THEM SEVERELY & FORMS FLAMM HYDROGEN GAS. CONT W/ANY
ALKALI/ACTIVE METAL MAY DEVELOP ENOUGH HEAT TO CAUSE FIRE IN
ADJACENT CO MBUST MATLS. EFTS OF OVEREXP: NAUS & VOMIT. INHAL OF
CONCENTATED HYDROCHLORIC ACID MAY BE FATAL, CAUSING SPASM, (ING 2)

Chemical Properties

HCC:C1
Spec Gravity:1
Solubility in Water:SOLUBLE
Appearance and Odor:TRANSPARENT SOLUTION WITH AN ACRID ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
BASES, AMINES, ALKALI METALS, COPPER, COPPER ALLOYS, ALUMINUM & HCL
CORRODES STEEL. WHEN CONCENTRATED (SUPP DATA)
Stability Condition to Avoid:ELEVATED TEMPERATURES MAY CAUSE CONTAINERS
TO BURST AND LIBERATE TOXIC FUMES OF HYDROGEN CHLORIDE GAS.
Hazardous Decomposition Products:WILL RELEASE TOXIC FUMES OF HYDROGEN
CHLORIDE GAS.

Disposal

Waste Disposal Methods:CONTACT LOCAL HAZARDOUS OR CHEMICAL WASTE
DISPOSAL AGENCY FOR REGULATION. DISPOSE OF I/A/W FEDERAL, STATE AND
LOCAL REGULATIONS .

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.